Skip to content

CMS137's Initiation rate has no chip, list or cases: case work follows Engagement only #697

Description

@Taleef7

CMS137 has two rates, and case work follows only one of them. Found in a live walk-through of the Maui sandbox as a case manager, 2026-09-23.

What is on screen

  • The CMS137 card, its status chips, the "Open cases" link and the work list all follow Engagement: 64 of 490, 13.1%.
  • Initiation, 181 of 490 (36.9%), appears exactly once: in the "CMS Measure Rate" box on /programs/cms137. There is no chip, list or case for it.

Why it matters

A patient who has not initiated treatment is a gap under Initiation. Case management cannot see that gap. The practice can read the Initiation rate but cannot work it.

Decision needed

  1. Add an Initiation chip and list beside Engagement, so both rates are workable.
  2. Show both rates on the card, and keep the case work on Engagement only.
  3. Say plainly on the card and the measure page that case work follows Engagement.

The first is the most useful and the most work. The third costs almost nothing, and at least stops the screen implying the measure has a single rate.

Activity

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    frontendmaui-pilotArising from the Maui pilot deploymentpilot-trustThe app states something to the user that is not truequestionFurther information is requested

    Projects

    No projects

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions