The Lab Compiler

A compiler for biological engineering. Describe experiments in Python, check the protocol, and produce a document or a robot program.

Lab Compiler is the Python compiler for laboratory work. A Protocol records materials, wells, steps, and optional sample identities and lineage. Compilation checks volumes, units, bindings, and sample declarations, then writes a printable document and code for the liquid handler you name.

Protocol containers, steps, and decks are expressed in Lab types. A Deck holds shared container requirements and can include a DeckLayout for each liquid handler. Compilation selects the layout, checks the handler's capabilities, and translates Lab equipment and placements into Opentrons or PyLabRobot configuration. Supported presets handle simple layouts. You do not need to construct SDK deck objects.

Install

Install the lab-compiler distribution with Python 3.11 or 3.12, and import it as lab:

pip install lab-compiler

The base package compiles printable documents. Install the optional SDK for your robot target:

pip install "lab-compiler[opentrons]"  # OT-2 and Flex
pip install "lab-compiler[star]"       # Hamilton STAR

Use "lab-compiler[opentrons,star]" to install both SDKs.

Write a protocol

A Protocol records what a scientist would write at the bench: the plates, what starts in each well, and every transfer and mix. This one prepares a two-fold dilution series of fluorescein in PBS, the standard curve for a plate reader.

from lab import Protocol, compile, uL
from lab.deck import Container, Deck, DeckSite
from lab.equipment import LiquidHandler
from lab.labware import PLATE_96

protocol = Protocol("fluorescein serial dilution")
sources = protocol.plate("sources", capacity=360 * uL)
assay = protocol.plate("assay", capacity=360 * uL)

fluorescein, pbs, waste = sources["A1"], sources["A2"], sources["A3"]
protocol.load(fluorescein, "10 µM fluorescein in PBS", volume=150 * uL)
protocol.load(pbs, "PBS", volume=300 * uL)

dilutions = [assay[f"A{column}"] for column in range(1, 7)]
protocol.transfer(fluorescein, dilutions[0], volume=100 * uL)
protocol.distribute(pbs, dilutions[1:], volume=50 * uL)

# Carry 50 µL down the row, mixing each well before the next transfer.
for previous, current in zip(dilutions, dilutions[1:]):
    protocol.transfer(previous, current, volume=50 * uL)
    protocol.mix(current, volume=40 * uL, cycles=3)
protocol.transfer(dilutions[-1], waste, volume=50 * uL)
protocol.manual("Read fluorescence at 485 nm excitation and 525 nm emission.")

deck = Deck(
    containers=(
        Container(id="sources", labware=PLATE_96, site=DeckSite.PLATES),
        Container(id="assay", labware=PLATE_96, site=DeckSite.PLATES),
    )
)
compiled = compile(protocol, deck=deck, liquid_handler=LiquidHandler.FLEX)

compile() checks every volume against the wells and the pipette, then writes a printable protocol and an Opentrons Flex program. The deck only says both plates sit in open plate positions; the Flex preset chooses the slots, tip rack, and pipette. Wells A1–A6 of the assay plate each finish with 50 µL.

Describe a deck

A DeckLayout states the equipment and positions instead of leaving them to a preset. This OT-2 deck places the dilution protocol's sources and assay plates in slots 1 and 2, a 300 µL tip rack in slot 3, and a P300 pipette on the left mount. It uses the same equipment and placement types as the deck layouts example.

from lab.deck import Deck, DeckLayout, Pipette, Placement, Slot, TipRack
from lab.equipment import LabwareModel, LiquidHandler, Mount, PipetteModel, TipRackModel
from lab.labware import PLATE_96, ContainerSpec

deck = Deck(
    containers=(
        ContainerSpec(id="sources", labware=PLATE_96),
        ContainerSpec(id="assay", labware=PLATE_96),
    ),
    layouts=(
        DeckLayout(
            liquid_handler=LiquidHandler.OT2,
            placements=(
                Placement(
                    container="sources",
                    model=LabwareModel.CORNING_96_360_UL,
                    location=Slot("1"),
                ),
                Placement(
                    container="assay",
                    model=LabwareModel.CORNING_96_360_UL,
                    location=Slot("2"),
                ),
            ),
            tip_racks=(
                TipRack(
                    id="tips",
                    model=TipRackModel.OPENTRONS_300_UL,
                    location=Slot("3"),
                ),
            ),
            pipettes=(
                Pipette(
                    model=PipetteModel.P300_SINGLE_GEN2,
                    mount=Mount.LEFT,
                    tip_racks=("tips",),
                ),
            ),
        ),
    ),
)

Compile the dilution protocol for that robot:

compiled = compile(protocol, deck=deck, liquid_handler=LiquidHandler.OT2)

Describe physical layouts in Lab

Use DeckLayout when equipment or placement needs to be explicit. Each layout names its LiquidHandler and places the same shared containers. All objects below belong to Lab:

Object Purpose
Placement A container's physical labware model, position, and optional well mapping
Slot, Rail, HolderSite A deck slot, carrier rail, or indexed site on a named holder
Carrier, Module Equipment that occupies a position and holds other resources
TipRack A tip model and its position
Pipette, Channel A mounted pipette or independent channel, with its assigned tip racks

Equipment models are typed identifiers from lab.equipment; each backend resolves the models it supports. A STAR layout can place a carrier at Rail(20) and a plate at HolderSite("plates", 3). An Opentrons layout can place the same logical container at Slot("2") or on a named module. The shared model does not impose one thermal device on every handler. Targets enforce their supported device counts, models, locations, and module footprints.

The deck layouts example prepares duplicate BSA standards and purified protein samples in a flat-bottom assay plate using a reservoir of prepared BCA working reagent. protocol() describes the transfers; deck() shares the container requirements and calls opentrons_layout() for OT-2 and Flex and hamilton_layout() for STAR. The logical source wells map to physical wells B1–B12 on each handler; STAR also specifies carriers, rails, and occupied carrier sites. Mixing, incubation, and absorbance reading remain an explicit operator handoff following the Pierce BCA guide. The example imports only Lab types and the Python standard library, with layouts to adapt to installed equipment.

from examples.deck_layouts import deck, protocol
from lab import compile
from lab.equipment import LiquidHandler

compiled = compile(protocol(), deck=deck(), liquid_handler=LiquidHandler.STAR)

The compiler rejects missing layouts, conflicting placements, invalid holder references, incompatible labware, and unsupported target features. It preserves the authored Lab deck in plan.json alongside the resolved backend configuration. Physical geometry comes from the selected equipment definitions; the STAR backend constructs and serializes the PyLabRobot resource hierarchy internally.

For Opentrons, place thermal labware on a supported Module. STAR layouts currently support one independent Channel and external thermal integration. Declare thermal containers in DeckLayout.external_thermal_resources and supply the async thermocycle callback when the generated run() executes. The callback is responsible for controlling the device and returning the plate to its original position. Compilation checks the declaration; the software preview only reports the request. On-deck Module models are not yet supported by the STAR backend.

By default, thermocycling matches the lid target to each block target within the device's heated lid range and turns lid heating off below that range. On Opentrons, the lid follows block targets at 37 °C and above; colder holds turn off the lid heater. Persistent thermocycler holds use the same rule, including setup and plating. An explicit lid_temperature keeps the lid at a fixed target throughout a profile. Successful profiles keep their final temperature settings; a failed Opentrons profile shuts down both controllers. External STAR thermal callbacks follow the same contract when lid_temperature=None.

Try it

The examples live in the source repository. With uv installed, set up Python 3.12 and both optional SDKs:

git clone https://github.com/MyersResearchGroup/LabCompiler.git
cd LabCompiler
uv sync --locked --all-extras --python 3.12
uv run --no-sync python -m examples.cloning --target manual
uv run --no-sync python -m examples.cloning --target ot2
uv run --no-sync python -m examples.deck_layouts --target star
uv run --no-sync python -m examples.deck_layouts --target ot2
uv run --no-sync python -m examples.deck_layouts --target flex

Use manual or ot2 for the cloning example. Its assembly recipe includes transfers below the current Flex preset's supported pipetting range. The deck layouts example supports ot2, flex, and star.

The cloning example writes separate assembly, transformation, and plating bundles under build/cloning/<target>, including for the manual target. The deck layouts example writes to build/decks/<target>. Both accept --out to choose a different output directory. Compilation never connects to hardware.

compile() writes the bundle to ~/.lab/<protocol>/<target>/. LAB_HOME replaces ~/.lab, and to chooses another directory. to=None returns the compilation without writing. Compiling the same protocol and target again replaces that bundle.

Compilation.write() writes these files to a chosen directory:

File Contents When written
protocol.html Printable protocol and setup instructions Every compilation
plan.json Recorded protocol, sample declarations, target configuration, bindings, and final volumes Every compilation
manifest.json Planned output samples and logical placements When the protocol declares outputs
protocol.py Generated robot program Robot targets

The manifest uses logical container and well names; physical bindings remain in plan.json. Rewriting an identical bundle succeeds. If any generated file would replace different contents, write() rejects the write before changing any bundle files.

Development

From the repository root:

uv sync --locked --all-extras --python 3.12
uv run --no-sync ruff check .
uv run --no-sync mypy
uv run --no-sync pytest

CI runs the OT-2 equivalence tests against a pinned PUDU revision. To compare against another checkout, set PUDU_SOURCE to its src directory. When this variable is set, missing PUDU source or the Opentrons SDK fails the run.

PUDU_SOURCE=/path/to/PUDU/src uv run --no-sync pytest -q tests/test_ot2_equivalence.py

See the release guide for package validation and PyPI publishing, and the release notes for changes and migration guidance.

About

Lab Compiler is a Python library for laboratory work. Write the experiment once. Compile it for any lab.

Topics

Resources

Stars

1 star

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages